Call 08046033631 87% Response Rate

our range

New Items

Honeywell Elevator Limit Switches

Honeywell Elevator Limit Switches

Rs 400  / PieceGet Best Price
Honeywell offer ZLD Limit Switches suitable for Elevator operations. Available @ very economical prices.
Riding on unfathomable volumes of industrial expertise, we are offering an excellent range of Elevator Final Limit Switch to our clients.

View Complete details

get quote request a call back
Pepperl + Fuchs Ml100-8-1000-rt/102/115 Diffuse Mode Sensor

Pepperl + Fuchs Ml100-8-1000-rt/102/115 Diffuse Mode Sensor

Price on Request

Product Brochure

Minimum Order Quantity1 Number
Model Name/NumberML100-8-1000-RT/102/115
BrandPepperl + Fuchs
Detection range0 ... 1000 mm
Reference targetstandard white, 100 mm x 100 mm
Light source & typeLED, modulated visible red light
ApprovalsCE, cULus Listed 57M3 (Only in association with UL Class 2 power supply; Type 1 enclosure
Protection degreeIP67
Connection2 m fixed cable
Operating voltage10 ... 30 V DC , class 2
Response time0.5 ms
Ambient temperature-30 ... 60 DegreeC
Housing MaterialPC (Polycarbonate)
Optical face materialPMMA
Massapprox. 50 g
We are authorised distributors of Honeywell Products and have stock of Pepperl & Fuchs ML100-8-1000-RT/102/115 Diffuse mode sensor at best prices. The ML100 series is characterized by its miniature housing with integral, all-metal threaded bushings. All versions are equipped with a visible red transmitter LED. This greatly simplifies installation and commissioning. The switching states are easily visible from all directions thanks to the highly visible LEDs.

View Complete details

get quote request a call back
Pepperl + Fuchs Ml7-8-h-140-rt/59/65a/115/136 Diffuse Mode Sensor

Pepperl + Fuchs Ml7-8-h-140-rt/59/65a/115/136 Diffuse Mode Sensor

Price on Request

Product Brochure

Minimum Order Quantity1 Number
BrandPepperl + Fuchs
Model Name/NumberML7-8-H-140-RT/59/65A/115/136
Connection Type2 m fixed cable
MaterialHousing: PC (Polycarbonate), Optical face: PMMA
Adjustment Range100 ... 1000 mm
Ambient Light LimitEN 60947-5-2
Detection range0 ... 1000 mm
DiameterApprox. 75 mm at a distance of 1000 mm
Light sourceLED
Reference targetStandard white, 100 mm x 100 mm
Response Time0.5 ms
WeightApprox. 50 g
ApprovalsCE, cULus Listed 57M3 (Only in association with UL Class 2 power supply; Type 1 enclosure)
We are authorised distributors of Honeywell Products and have stock of Pepperl & Fuchs ML7-8-H-140-RT/59/65A/115/136 Diffuse mode sensor at best prices. The ML100 series is characterized by its miniature housing with integral, all-metal threaded bushings. All versions are equipped with a visible red transmitter LED. This greatly simplifies installation and commissioning. The switching states are easily visible from all directions thanks to the highly visible LEDs.

View Complete details

get quote request a call back
Honeywell HCD2RMCVXXXXXXX Room Carbon Dioxide Transmitter

Honeywell HCD2RMCVXXXXXXX Room Carbon Dioxide Transmitter

Price on Request

Product Brochure

Minimum Order Quantity1 Number
BrandHoneywell
Model Name/NumberHCD2RMCVXXXXXXX
Gas Type DetectedCarbon dioxide (CO2)
Sensor TypeDual wavelength non-dispersive infrared (NDIR)
Sensor Accuracy+- 50 ppm + 3% of reading
Measurement Range0-2000 ppm (default), adjustable 1000-5000 ppm
Pressure Dependency< 1% of reading / kPa
Response Time90 seconds (T90)
Warm-Up Time1 minute
Sensor Coverage Area100 m2 (1000 ft2) typical
Sensor Life Span>10 years
Transmitter Accuracy+-0.25% of span
Power Supply24 Vdc +-20% or 24 Vac +-10% (non-isolated half-wave rectified)
Protection CircuitryReverse voltage and transient protected
Input Voltage EffectNegligible over specified operating range
Output Signal Type4-20 mA (3-wire), 0-5 or 0-10 Vdc (field selectable)
Current ConsumptionCurrent: 75 mA @ 24 Vdc max, 150 mA @ 24 Vac max Voltage: 50 mA @ 24 Vdc max, 100 mA @ 24 Vac max
Output Drive @ 24 VdcCurrent: 550 Ohm max Voltage: 10,000 Ohm min
Ambient Operating Range-10 to 50 Deg.C (14 to 122 Deg.F), 5 to 90 %RH non-condensing
Storage Conditions30 to 70 Deg.C (-22 to 158 Deg.F), 5 to 90 %RH non-condensing
LCD Display Unitsppm (CO2), Deg.C/Deg.F (optional temperature/setpoint)
Display Range0-5000 ppm, 0 to 50Deg.C, 0 122 Deg.F
Display Size35mm W x 15mm H (1.4" x 0.6")
Digit Height2-line x 8 character
EnclosureWhite ABS, IP30 (NEMA 1) 84mm W x 119mm H x 29mm D
ApprovalsCE
Product DescriptionRoom Carbon Dioxide Transmitter
DisplayViewable LCD
The room CO2 transmitter device uses a highly accurate and reliable nondispersive infrared (NDIR) sensor in an attractive, low profile enclosure for room applications to monitor CO2 levels. The sensor uses dual wavelength optics and LTA (long term adjustment) signal processing technology to deliver industry leading long-term accuracy and reliability. These technology features ensure optimum measurement stability for both periodic and constant occupancy applications, so the device is equally suitable for a classroom or a hospital room.
Standard features include a field selectable output signal of either 4-20 mA, 0-5 Vdc or 0-10 Vdc for the highest versatility, programmable CO2 measurement span, a backlit alphanumeric LCD and easy menu operation for configuration. Optional features include a resistive temperature sensor output (with LCD display of temperature in either °C or °F), 2 button setpoint adjustment, a control relay with programmable setpoint, hysteresis and time delay, and a dry-contact override switch.

View Complete details

get quote request a call back

EXPLORE MORE CATEGORIES