Call 08046033631 80% Response Rate

our range

New Items

City Technology Mox4 Medical Sensor

City Technology Mox4 Medical Sensor

Rs 5,999  / PieceGet Best Price

Product Brochure

BrandCity Technology
Warranty12 Months
Weight42 g (nominal)
Model NumberMox4
Operating PrinciplePartial pressure electrochemical
Output9 mV to 13 mV in 210 mBar O2
Measurement Range0 mBar to 1500 mBar O2
Response Time (T90)<15 s (air to 100% O2)
Baseline Offset<200 Micro Volte
Temperature CompensationPartial compensation for Teledyne T-7 equivalence
External Load Resistor10 k Ohm minimum
ConnectorUK Data Socket AMP (P/N 520257-2)
Housing MaterialWhite ABS
Operating Temperature Range-20 DegreeC to +50 DegreeC
Operating Pressure Range0.5 Bar to 2.0 Bar
Operating Humidity Range0% to 99% RH noncondensing
Long-Term Ouput Drift in 100% O2< 5% signal loss/year
Recommended Storage Temperature-10 DegreeC to +40 DegreeC

CiTiceLs are designed for operation in a wide range of environments and harsh conditions. However, it is important that exposure to high concentrations of solvent vapours is avoided, both during storage, fitting into instruments and operation. When using sensors with printed circuit boards (PCBs), degreasing agents should be used before the sensor is fitted. Do not glue directly on or near the CiTiceL as the solvent may cause crazing of the plastic
These sensors are designed to be used to monitor the partial pressure of oxygen in anaesthesia (not including xenon), critical care, neonatal incubators, and general oxygen monitors.

Key Features and Benifits :

  • Meets the requirements of ISO 80601-2-55
  • Linear output from 0 % to 100 % O2
  • 13-month warranty
  • RoHS compliant

View Complete details

get quote request a call back
Honeywell Elevator Limit Switches

Honeywell Elevator Limit Switches

Rs 400  / PieceGet Best Price

Minimum Order Quantity: 10 Piece

MaterialThermoplastic/Plastic
Switch TypeRotary Push Button
BrandHoneywell
Usage/ApplicationMachine tools, conveyors, elevators, cranes and hoists, Packaging machinery and process equipment
Current Rating (Amps)5
Power/Voltage (V)120
Maximum Speed0.05mm-2m/s
Material/BodyMetal
FeatureSealing up to IP/65/ IP 67, International conduit sizes, Design for ease of installation
Frequency120 ops/min
TypeElevator Limit Switch
Honeywell offer ZLD Limit Switches suitable for Elevator operations. Available @ very economical prices.
Riding on unfathomable volumes of industrial expertise, we are offering an excellent range of Elevator Final Limit Switch to our clients.

View Complete details

get quote request a call back
Pepperl + Fuchs Ml100-8-1000-rt/102/115 Diffuse Mode Sensor

Pepperl + Fuchs Ml100-8-1000-rt/102/115 Diffuse Mode Sensor

Price on Request

Product Brochure

Minimum Order Quantity1 Number
Model Name/NumberML100-8-1000-RT/102/115
BrandPepperl + Fuchs
Detection range0 ... 1000 mm
Reference targetstandard white, 100 mm x 100 mm
Light source & typeLED, modulated visible red light
ApprovalsCE, cULus Listed 57M3 (Only in association with UL Class 2 power supply; Type 1 enclosure
Protection degreeIP67
Connection2 m fixed cable
Operating voltage10 ... 30 V DC , class 2
Response time0.5 ms
Ambient temperature-30 ... 60 DegreeC
Housing MaterialPC (Polycarbonate)
Optical face materialPMMA
Massapprox. 50 g
We are authorised distributors of Honeywell Products and have stock of Pepperl & Fuchs ML100-8-1000-RT/102/115 Diffuse mode sensor at best prices. The ML100 series is characterized by its miniature housing with integral, all-metal threaded bushings. All versions are equipped with a visible red transmitter LED. This greatly simplifies installation and commissioning. The switching states are easily visible from all directions thanks to the highly visible LEDs.

View Complete details

get quote request a call back
Pepperl + Fuchs Ml7-8-h-140-rt/59/65a/115/136 Diffuse Mode Sensor

Pepperl + Fuchs Ml7-8-h-140-rt/59/65a/115/136 Diffuse Mode Sensor

Price on Request

Product Brochure

Minimum Order Quantity1 Number
BrandPepperl + Fuchs
Model Name/NumberML7-8-H-140-RT/59/65A/115/136
Connection Type2 m fixed cable
MaterialHousing: PC (Polycarbonate), Optical face: PMMA
Adjustment Range100 ... 1000 mm
Ambient Light LimitEN 60947-5-2
Detection range0 ... 1000 mm
DiameterApprox. 75 mm at a distance of 1000 mm
Light sourceLED
Reference targetStandard white, 100 mm x 100 mm
Response Time0.5 ms
WeightApprox. 50 g
ApprovalsCE, cULus Listed 57M3 (Only in association with UL Class 2 power supply; Type 1 enclosure)
We are authorised distributors of Honeywell Products and have stock of Pepperl & Fuchs ML7-8-H-140-RT/59/65A/115/136 Diffuse mode sensor at best prices. The ML100 series is characterized by its miniature housing with integral, all-metal threaded bushings. All versions are equipped with a visible red transmitter LED. This greatly simplifies installation and commissioning. The switching states are easily visible from all directions thanks to the highly visible LEDs.

View Complete details

get quote request a call back
City Technology Mox1 Medical Sensor

City Technology Mox1 Medical Sensor

Rs 5,999  / PieceGet Best Price

Minimum Order Quantity: 1 Piece

Product Brochure

BrandCity Technology
Model NumberMox1
Operating PrinciplePartial pressure electrochemical
Output9 mV to 13 mV in 210 mBar O2
Measurement Range0 mBar to 1500 mBar O2
Response Time (T90)<15 s (air to 100% O2)
Baseline Offset<200 Micro Volte
Temperature Compensation<2% O2 equivalent (0 Deg C to 40 Deg C)
External Load Resistor10 k Ohm minimum
Connector3-pin Molex Header
Housing MaterialWhite ABS
Weight39 g (nominal)
Operating Temperature Range-20 Deg C to +50 Deg C
Operating Pressure Range0.5 Bar to 2.0 Bar
Operating Humidity Range0% to 99% RH noncondensing
Long-Term Ouput Drift in 100% O2< 5% signal loss/year
Recommended Storage Temperature-10 Deg C to +40 Deg C
CiTiceLs are designed for operation in a wide range of environments and harsh conditions. However, it is important that exposure to high concentrations of solvent vapours is avoided, both during storage, fitting into instruments and operation. When using sensors with printed circuit boards (PCBs), degreasing agents should be used before the sensor is fitted. Do not glue directly on or near the CiTiceL as the solvent may cause crazing of the plastic
These sensors are designed to be used to monitor the partial pressure of oxygen in anaesthesia (not including xenon), critical care, neonatal incubators, and general oxygen monitors.

Key Features and Benifits :

  • Meets the requirements of ISO 80601-2-55
  • Linear output from 0 % to 100 % O2
  • 13-month warranty
  • RoHS compliant

View Complete details

get quote request a call back
Honeywell HD200MH1W0 Indoor Air Quality Monitor

Honeywell HD200MH1W0 Indoor Air Quality Monitor

Price on Request

Product Brochure

Minimum Order Quantity1 Piece
Model Name/NumberHD200MH1W0
Usage/ApplicationIndoor Air Quality
BrandHoneywell
Operating Temperature0 to 70 deg. C
Operating Humidity Range0 to 90% Rh. (Non-condensing
Display Type3.5" TFT
CombinationTemp, RH, PM2.5, TVOC, CO2
CommunicationMODBUS; RS-485
CertificateRoHS
Power Adaptoryes
ColourWhite
IAQ Monitor Power Supply12 VDC

Honeywell Indoor Air Quality Monitor is advanced with modular architecture design and configured with a comprehensive array of multi-sensors to measure various air quality parameters viz. Particulate Matter (PM2.5 and PM10), Carbon Dioxide (CO2), Total Volatile Organic Compound (TVOC), Temperature (T), and Relative humidity (Rh) in a single device.

The indoor air quality monitor uses an ‘active suction method’, draws ‘air sample’ which enables laminar flow across the array of sensors for better accuracy. The device is BMS Compatible via RS-485 port using MODBUS protocol.

The indoor air quality monitor is pre-configurable with optional sensors viz. Formaldehyde (HCHO), Ozone (O3)*, NOx*, and SOx* apart from the standard configuration.

It is suitable for intelligent buildings and systems, air quality data collection systems, green building evaluation systems, and ventilation systems.

 

FEATURES AND BENEFITS

  • Wide array of configurable hi-accuracy sensors
  • Modular architecture: ‘5+2’ for optional configuration
  • Active sampling with ‘Maglev’ fan for climate and gas sensor
  • Advanced Honeywell particulate sensor. laser-based light scattering particle sensing
  • Large 3.5” TFT touchscreen for clear visual indication
  • AQI parameter display on screen
  • BMS compatible

View Complete details

get quote request a call back
  • Honeywell Y-Strainer (YS-SLF4/YS-SF5)
  • Honeywell Y-Strainer (YS-SLF4/YS-SF5)
Honeywell Y-Strainer (YS-SLF4/YS-SF5)

Honeywell Y-Strainer (YS-SLF4/YS-SF5)

Price on Request

Product Brochure

Model Name/NumberYS-SLF4/YS-SF5
End ConnectionFlange End
Cover GasketEPDM
BrandHoneywell
Nominal Pressure RatingPN16, PN10
Size RangeDN50 to DN600
MediumChilled and hot water 50% glycol solution
Medium temperature-10 to 120 degree C
body MaterialQT450-10
Bonnet MaterialQT450-10
Filter ScreenSS304

Honeywell Y-type strainer is widely used in water application and is used for protecting valve and other equipments from scrap and impurities in the system.

FEATURES
. Ductile iron body with epoxy coating
. Stainless Steel Filter Stem

View Complete details

get quote request a call back
Honeywell HN200MH1W0 Indoor Air Quality Monitor

Honeywell HN200MH1W0 Indoor Air Quality Monitor

Price on Request

Product Brochure

Model Name/NumberHN200MH1W0
Usage/ApplicationIndoor Air Quality
BrandHoneywell
Operating Temperature0 to 70 DegreeC
Operating Humidity Range0 to 90% Rh. (Non-condensing
Displayyes
Combinationemp, RH, PM2.5, TVOC, CO2
CommunicationMODBUS; RS-485
CertificateRoHS
Power AdaptorYes
ColourColour
IAQ Monitor Power Supply12 VDC

Honeywell Indoor Air Quality Monitor is advanced with modular architecture design and configured with a comprehensive array of multi-sensors to measure various air quality parameters viz. Particulate Matter (PM2.5 and PM10), Carbon Dioxide (CO2), Total Volatile Organic Compound (TVOC), Temperature (T), and Relative humidity (Rh) in a single device.

The indoor air quality monitor uses an ‘active suction method’, draws ‘air sample’ which enables laminar flow across the array of sensors for better accuracy. The device is BMS Compatible via RS-485 port using MODBUS protocol.

The indoor air quality monitor is pre-configurable with optional sensors viz. Formaldehyde (HCHO), Ozone (O3)*, NOx*, and SOx* apart from the standard configuration.

It is suitable for intelligent buildings and systems, air quality data collection systems, green building evaluation systems, and ventilation systems.

 

FEATURES AND BENEFITS

  • Wide array of configurable hi-accuracy sensors
  • Modular architecture: ‘5+2’ for optional configuration
  • Active sampling with ‘Maglev’ fan for climate and gas sensor
  • Advanced Honeywell particulate sensor. laser-based light scattering particle sensing
  • Large 3.5” TFT touchscreen for clear visual indication
  • AQI parameter display on screen
  • BMS compatible

View Complete details

get quote request a call back
Honeywell HCD2RMCVXXXXXXX Room Carbon Dioxide Transmitter

Honeywell HCD2RMCVXXXXXXX Room Carbon Dioxide Transmitter

Price on Request

Product Brochure

Minimum Order Quantity1 Number
BrandHoneywell
Model Name/NumberHCD2RMCVXXXXXXX
Gas Type DetectedCarbon dioxide (CO2)
Sensor TypeDual wavelength non-dispersive infrared (NDIR)
Sensor Accuracy+- 50 ppm + 3% of reading
Measurement Range0-2000 ppm (default), adjustable 1000-5000 ppm
Pressure Dependency< 1% of reading / kPa
Response Time90 seconds (T90)
Warm-Up Time1 minute
Sensor Coverage Area100 m2 (1000 ft2) typical
Sensor Life Span>10 years
Transmitter Accuracy+-0.25% of span
Power Supply24 Vdc +-20% or 24 Vac +-10% (non-isolated half-wave rectified)
Protection CircuitryReverse voltage and transient protected
Input Voltage EffectNegligible over specified operating range
Output Signal Type4-20 mA (3-wire), 0-5 or 0-10 Vdc (field selectable)
Current ConsumptionCurrent: 75 mA @ 24 Vdc max, 150 mA @ 24 Vac max Voltage: 50 mA @ 24 Vdc max, 100 mA @ 24 Vac max
Output Drive @ 24 VdcCurrent: 550 Ohm max Voltage: 10,000 Ohm min
Ambient Operating Range-10 to 50 Deg.C (14 to 122 Deg.F), 5 to 90 %RH non-condensing
Storage Conditions30 to 70 Deg.C (-22 to 158 Deg.F), 5 to 90 %RH non-condensing
LCD Display Unitsppm (CO2), Deg.C/Deg.F (optional temperature/setpoint)
Display Range0-5000 ppm, 0 to 50Deg.C, 0 122 Deg.F
Display Size35mm W x 15mm H (1.4" x 0.6")
Digit Height2-line x 8 character
EnclosureWhite ABS, IP30 (NEMA 1) 84mm W x 119mm H x 29mm D
ApprovalsCE
Product DescriptionRoom Carbon Dioxide Transmitter
DisplayViewable LCD
The room CO2 transmitter device uses a highly accurate and reliable nondispersive infrared (NDIR) sensor in an attractive, low profile enclosure for room applications to monitor CO2 levels. The sensor uses dual wavelength optics and LTA (long term adjustment) signal processing technology to deliver industry leading long-term accuracy and reliability. These technology features ensure optimum measurement stability for both periodic and constant occupancy applications, so the device is equally suitable for a classroom or a hospital room.
Standard features include a field selectable output signal of either 4-20 mA, 0-5 Vdc or 0-10 Vdc for the highest versatility, programmable CO2 measurement span, a backlit alphanumeric LCD and easy menu operation for configuration. Optional features include a resistive temperature sensor output (with LCD display of temperature in either °C or °F), 2 button setpoint adjustment, a control relay with programmable setpoint, hysteresis and time delay, and a dry-contact override switch.

View Complete details

get quote request a call back
  • Honeywell Non Return Valve
  • Honeywell Non Return Valve
  • Honeywell Non Return Valve
  • Honeywell Non Return Valve
Honeywell Non Return Valve

Honeywell Non Return Valve

Price on Request

Product Brochure

Minimum Order Quantity1 Piece
brandHoneywell
Model no.BSV4-CWD Series
SizesDN50-DN300
Nominal pressurePN16
Medium Temperature10 DegreeC~ +110 DegreeC Maximum
Body MaterialIS:210,Gr. FG200
Seat MaterialEPDM
Shaft MaterialASTM A276, GR. SS410
Spring MaterialAISI 302
O-Rings MaterialNITRILE / EPDM
Plug MaterialM.S. (crome plated)
Fasteners MaterialStainless Steel
Plates MaterialD.I (Lapped)
Seal Test pressure17bar
Shell Test pressure24bar
Flange standardISO7005-1(GB/T9113) / IS:1538
Medium TypeWater

The Honeywell Non Return Valve BSV4-CWD Dual Plate Check Valves is designed for Chilled & Hot Water for purpose non-return valve that is stronger, lighter in weight and smaller in size as compared to other Check valve.

 

Features

• Wide Size range (DN50…DN300)
• Cast iron Body
• Lapped Ductile Iron disc
• Wafer type and flange type Connection

View Complete details

get quote request a call back

EXPLORE MORE CATEGORIES