Usage/Application | Medical Ventilators |
Brand | Envitec |
Model Number | E1000470 |
Model Name/Number | Flow sensor SpiroQuant H |
Media | Oxygen |
Material | Plastic |
Connection Type | Gold plated 4 pin |
Weight | Approx 10 g |
Additional Information:
View Complete details
Product Brochure
Usage/Application | Medical |
Brand | Envitec |
Model Name/Number | E07-00-001 Flow sensor SpiroQuant H |
Media | Air |
Material | Housing parts: MABS; Contact pins: gold-plated; Hot-wires: platin |
Weight | Approx. 10 g |
Flow Range | 0-160 slpm |
Additional Information:
View Complete details
Product Brochure
Model/ Part Number | OOM202 |
Target gases | Oxygen |
Measuring Range | 0-100% |
Operating Voltage | 5V |
Usage/Application | Hospital |
Brand | Honeywell Envitec |
Size | Compact |
Operating Humidity | 0-95%Rh |
Packaging Type | 1 |
We are distributor of Honeywell Envitec Oxygen Sensor OOM202 used in ventilator & other medical industries.
Additional Information:
View Complete details
Minimum Order Quantity: 01 Piece
Product Brochure
Model / Part Number | OOM102-1 |
Brand | Honeywell Envitec |
Target gases | OXYGEN |
Model Number | OOM102-1 |
Measuring Range | 0-100% |
Operating Voltage | 5V |
Oxygen Pressure Range | 2 bar |
View Complete details
Minimum Order Quantity: 01 Piece
Product Brochure
Model / Part Number | OOM201 |
Brand | Honeywell Envitec |
Target gases | OXYGEN |
Model Number | OOM201 |
Measuring Range | 0-100% |
Output Current ( in mA) | 14 mV ... 20.7 mV (Dual Cathode), load 600 Ohms |
Oxyegen pressure Range | 2 bar |
Warranty | 12 months |
Dimensions | 29 mm dia |
Usage/ Application | Medical Ventilators |
Response Time | < 12 s to 90 % of final value |
Modbus Output | NA |
View Complete details
Product Brochure
Brand | Honeywell Envitec |
Model Number | Oxiquant S |
Target gases | Oxygen |
Operating Voltage | MV |
Operating Oxygen Range | 0-100% |
Oxygen Pressure Range | 750 - 1250 hPa |
Material | PVC |
Application | Hospital |
Weight | 90G |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Brand | City Technology |
Warranty | 12 Months |
Weight | 39 g (nominal) |
Operating Temperature | -20 DegreeC to +50 DegreeC |
Operating Principle | Partial pressure electrochemical |
Output | 9 mV to 13 mV in 210 mBar O2 |
Measurement Range | 0 mBar to 1500 mBar O2 |
Response Time (T90) | <15 s (air to 100% O2) |
Baseline Offset | <200 Micro Volt |
Temperature Compensation | <2% O2 equivalent (0 DegreeC to 40 DegreeC) |
External Load Resistor | 10 k Ohm minimum |
Connector | 3-pin Molex Header |
Housing Material | White ABS |
Operating Pressure Range | 0.5 Bar to 2.0 Bar |
Operating Humidity Range | 0% to 99% RH noncondensing |
Long-Term Ouput Drift in 100% O2 | < 5% signal loss/year |
Recommended Storage Temperature | -10 DegreeC to +40 DegreeC |
CiTiceLs are designed for operation in a wide range of environments and harsh conditions. However, it is important that exposure to high concentrations of solvent vapours is avoided, both during storage, fitting into instruments and operation. When using sensors with printed circuit boards (PCBs), degreasing agents should be used before the sensor is fitted. Do not glue directly on or near the CiTiceL as the solvent may cause crazing of the plastic
These sensors are designed to be used to monitor the partial pressure of oxygen in anaesthesia (not including xenon), critical care, neonatal incubators, and general oxygen monitors.
Key Features and Benifits :
View Complete details
Product Brochure
Brand | City Technology |
Warranty | 12 Months |
Weight | 42 g (nominal) |
Model Number | Mox4 |
Operating Principle | Partial pressure electrochemical |
Output | 9 mV to 13 mV in 210 mBar O2 |
Measurement Range | 0 mBar to 1500 mBar O2 |
Response Time (T90) | <15 s (air to 100% O2) |
Baseline Offset | <200 Micro Volte |
Temperature Compensation | Partial compensation for Teledyne T-7 equivalence |
External Load Resistor | 10 k Ohm minimum |
Connector | UK Data Socket AMP (P/N 520257-2) |
Housing Material | White ABS |
Operating Temperature Range | -20 DegreeC to +50 DegreeC |
Operating Pressure Range | 0.5 Bar to 2.0 Bar |
Operating Humidity Range | 0% to 99% RH noncondensing |
Long-Term Ouput Drift in 100% O2 | < 5% signal loss/year |
Recommended Storage Temperature | -10 DegreeC to +40 DegreeC |
CiTiceLs are designed for operation in a wide range of environments and harsh conditions. However, it is important that exposure to high concentrations of solvent vapours is avoided, both during storage, fitting into instruments and operation. When using sensors with printed circuit boards (PCBs), degreasing agents should be used before the sensor is fitted. Do not glue directly on or near the CiTiceL as the solvent may cause crazing of the plastic
These sensors are designed to be used to monitor the partial pressure of oxygen in anaesthesia (not including xenon), critical care, neonatal incubators, and general oxygen monitors.
Key Features and Benifits :
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Measurement Range | 90% |
Brand | Honeywell Envitec |
Model Number | OOM204 |
Oxygen Pressure Range | 0.6 bar to 2 bar (ppO2 0 to 1250 mbar O2) |
Accuracy | meets ISO 80601-2-55 requirements |
Application | Hospital |
Weight | approximately 28 grams |
Nominal Sensor Lifetime | Greater than or equal to 500000 % volume oxygen hours |
Output in ambient air | 9 mV to 13.5 mV (each of two channels) |
Output difference | 1.25 mV (between the two channels) |
Electrical interface | 3 pin (Molex 22-11-1031) |
Repeatability | < 1 % volume O2 at constant temperature and pressure |
Linearity error | < 3 % relative |
Response time | < 12 s to 90 % of final value |
Influence of humidity | -0.03 % rel. per % RH at 25 Deg C |
Operating temperature | 0 Deg C to +50 Deg C |
Temperature compensation | built-in NTC compensation |
Operating humidity | 0 % to 99 % RH non-condensing |
Storage temperature | -20 Deg C to +50 Deg C |
Warm-up time | < 30 minutes, after replacement of sensor |
Part number | 01-00-0097 |
Honeywell Envitec Oxygen Sensor OOM204
Use the advantages:
• Compliant with European MDD (CE certification)
• Meets ISO 80601-2-55
• Designed and manufactured according to EN ISO 13485
• Accurate and reliable fast response
• Resistant to N2O
• Excellent signal stability
• High product quality
• Short delivery times
• Technical support
• Made in Germany
• FDA cleared
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Brand | City Technology |
Weight | <16 g |
Model/ Part Number | AAY80-390 (40XV) |
Technology | Electrochemical |
Measurement Range | 1-25% vol. O2 |
Maximum Overload | 30% vol. O2 |
Output Signal* | 0.10 +- 0.02 mA in Air |
Response Time (T90) | <15 Seconds |
Zero Current (Offset) | <0.6% vol. O2 |
Linearity | Can be considered linear in many cases. |
Recommended Load Resistor | 100 Ohm |
Casing Material | ABS |
Orientation Sensitivity | <0.2% vol. O2 equivalent |
Operating Temperature Range | -20 DegreeC to +50 DegreeC (up to 3 months continuous across RH range) |
Recommended Storage Temp | 0 DegreeC to 20 DegreeC |
Thermal Transient | <23.5% vol. O2 |
Operating Pressure Range | Atmospheric +- 20% |
Pressure Coefficient | <0.02% signal/mbar |
Pressure Transient | <200% signal change |
Relative Humidity Range | (at 0 DegreeC to 20 DegreeC) |
Long Term Output Drift* | <2% signal/month Typically <5% over operating life |
Oxygen Sensor AAY80-390 (40XV)
Key Features and Benefits :
• False alarm immunity
• Enhanced response time in extreme applications
• Reliably meets stated life
• Superior environmental performance
Typical Applications
General purpose, portable or fixed life safety.
Poisons
CiTiceLs are designed for operation in a wide range of environments and harsh conditions. However it is important that exposure to high concentrations of solvent vapours is avoided, both during storage, fitting into instruments, and operation. When using sensors with printed circuit boards (PCBs), degreasing agents should be used before the sensor is fitted. Do not glue directly on or near the CiTiceL as the solvent may cause crazing of the plastic.
Cross Sensitivity Data
Toxic gases at TLV levels will have no cross-sensitivity effect on Oxygen CiTiceLs. At very high levels (i.e. percent levels), highly oxidising gases (e.g. ozone, chlorine) will interfere to the extent of their oxygen equivalent, but most other commonly occurring gases will have no effect.
Acid Gases
IMPORTANT NOTE: Acid gases such as CO2 and SO2 will be absorbed by the electrolyte and tend to increase the flux of oxygen to the electrode. This gives an enhanced oxygen signal of approximately 0.3% of signal per 1% CO2. Oxygen CiTiceLs are not suitable for continuous operation in concentrations of CO2 above 25%.
View Complete details
Minimum Order Quantity: 01 Piece
Product Brochure
Brand | Honeywell Envitec |
Target gases | OXYGEN |
Model Number | E01-00-0098 (OOM110) |
Measuring Range | 0-100% |
Gas Flow Rate | N |
Operating Voltage | 5V |
Operating Oxygen Range | 0-100 |
Oxygen Pressure Range | 2 bar |
Diameter | 40.9 mm |
Accuracy | Linearity error < 3 % relative |
Warranty | 12 months,12 months |
Material | PVC |
Usage/ Application | Medical Ventilators |
Application | Hospital |
Response Time | < 12 s to 90 % of final value |
Weight | approximately 50 grams,approximately 50 grams |
HART Protocol | No |
View Complete details
Product Brochure
Target gases | oxygen |
Model Name/Number | AO2 |
Measuring Range | 0-100% O2 |
Material | Red ABS |
Operating Voltage | 5V |
Usage/Application | Hospital |
Brand | City Technology (Honeywell) |
Color | Red |
Size | Compact |
Operating Humidity | 0-95%Rh |
Additional Information:
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Usage/Application | Law Enforcement Agencies |
Brand | AlcoQuant |
Measurement Range | 0 to 5.5 BAC* |
Features | PIN-protected, Flow test mode, Quick updates via USB |
Display | LCD Display |
Mouthpiece | Single-use EnviteC mouthpiece (Types S and D) |
Temperature Range | -5 DegreeC to 45 DegreeC |
Dimensions | 195 mm x 60 mm x 47 mm |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Brand | Honeywell |
Display | 0.1% oxygen resolution |
Measuring range | 0 - 100% Oxygen |
Accuracy | < 1% volume O2 , when calibrated at 100% vol. O2 |
Response time | < 12 seconds to 90% of final value |
Ambient pressure | 750 to 1250 hPa |
Operating temperature | 0-50 deg C |
Battery Type | Li-ion 3.6 V 2900 mAh |
Weight | 330 g |
Dimensions (device) | 160 mm (H) x 72 mm (W) x 39 mm (D) |
Protection class | IP54 |
View Complete details