Andheri East, Mumbai, Maharashtra
GST No. 27AZMPM0516E1ZJ
Call 08046033631 78% Response Rate
Minimum Order Quantity: 1 Piece
Product Brochure
Transducer Type | Pressure Transducer |
Brand | Honeywell |
Part Number | PX2, PX3, GPT, MIPS |
Product Type | Pressure Transmitter |
Automation Grade | Semi-Automatic |
Power Supply | 230 V |
Output Signal (mA) | 4~20 mA |
Voltage (V) | 230 |
Pressure Range | 1 bar to 70 bar |
Temperature Range | -40 DegreeC to 125 DegreeC |
Series | PX2, PX3, GPT, MIPs |
Material | SS, brass |
Response time | <2 ms |
Condition | New |
Country of Origin | Made in India |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Brand | Honeywell |
Product Series | ABP Series Amplified Basic |
Transfer Function | 10% to 90% of Vsupply (analog) |
Part Number | ABPDANV150PGAA5 |
Model | ABPDANV150PGAA5 |
Solder reflow | J-STD-020-D.1 Moisture Sensitivity Level 1 (unlimited shelf life when stored at <30 DegreeC/85 %RH) |
Pressure Port | Single axial barbed port |
Output Type | Analog |
Shock | 100 g, 6 ms duration |
Life | 1 million pressure cycles minimum |
Vibration | 15 g, 10 Hz to 2 kHz |
Package | DIP (Dual Inline Pin) |
View Complete details
Product Brochure
Brand | Honeywell |
Accuracy | +-0.5%FSS |
Pressure Range | 5MPa to 35MPa |
Ingress protection | up to IP67 |
Output | 4-20mA |
Dielectric Strength | 750 Vac, 1 min. |
Response time | <2 ms |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Brand | Honeywell |
Part Number | MIPCG1XX001BACHX |
Pressure Range | 1 bar |
Current | 4 mA to 20 mA |
Startup time | 7 ms |
Vibration | 20 G sweep, 10 Hz to 2000 Hz at 25deg C |
Electrical connector material | PBT 30 %GF (UL V-0) |
Pressure Port Type | G1/4 A-G3 (ISO 1179-3) |
Current consumption | 6.5 mA +-1 mA |
Life | >10 million full scale pressure cycles |
Ingress protection: Metri-Pack 150 versions | IP65, IP67 |
Typical response time | 2 ms |
Accuracy BFSL3 | +-0.25 %FSS |
Supply voltage (Vs) | 8 Vdc to 30 Vdc1 |
Over/reverse voltage | +-35 Vdc |
Total Error Band | +-1.0 %FSS (-20deg C to 85deg C) +-2.0 %FSS (-40deg C to 125deg C) |
Operating temperature range | -40deg C to 125deg C |
Long term stability (1000 hr, 25deg C) | +-0.25 %FSS |
Typical output resolution | 0.05 % Full Scale Pressure |
Shock | 100 G per MIL-STD-202, Method 213, Cond. C at 25deg C |
Wetted materials: port diaphragm external seal for ports | stainless steel 304L stainless steel 316L nitrile -30deg C to 100deg C |
Cable material (jacket and insulation) | TPE (Thermoplastic Elastomer) flame retardant-type cable is FT1 rated per CSA AWM-I-A/B-II-A/B speci |
Electrical Connector Type | DIN-C, Standard (EN175301-803C) |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Brand | Honeywell |
Part Number | MIPCG1XX025BSCHX |
Pressure Range | 25 bar |
Supply voltage (Vs) | 8 Vdc to 30 Vdc1 |
Shock | 100 G per MIL-STD-202, Method 213, Cond. C at 25deg C |
Cable material (jacket and insulation) | TPE (Thermoplastic Elastomer) flame retardant-type cable is FT1 rated per CSA AWM-I-A/B-II-A/B speci |
Pressure Port Type | G1/4 A-G3 (ISO 1179-3) |
Current consumption | 6.5 mA +-1 mA |
Total Error Band | +-1.0 %FSS (-20deg C to 85deg C) +-2.0 %FSS (-40deg C to 125deg C) |
Accuracy BFSL3 | +-0.25 %FSS |
Long term stability (1000 hr, 25deg C) | +-0.25 %FSS |
Startup time | 7 ms |
Typical output resolution | 0.05 % Full Scale Pressure |
Operating temperature range | -40deg C to 125deg C |
Life | >10 million full scale pressure cycles |
Vibration | 20 G sweep, 10 Hz to 2000 Hz at 25deg C |
Typical response time | 2 ms |
Current | 4 mA to 20 mA |
Electrical Connector Type | DIN-C, Standard (EN175301-803C) |
Ingress protection: Metri-Pack 150 versions | IP65, IP67 |
Wetted materials: port diaphragm external seal for ports | stainless steel 304L stainless steel 316L nitrile -30deg C to 100deg C |
Electrical connector material | PBT 30 %GF (UL V-0) |
Over/reverse voltage | +-35 Vdc |
MIPCG1XX010BSCHX Honeywell Pressure Transducers offers a heavy duty and media-isolated pressure transducer in a compact, stainless steel construction for use with a wide range of media including aggressive fluids and water. The Honeywell MIPCG1XX010BSCHX Pressure Transducers provides a cost-competitive solution for wide-ranging potential applications in tough environments.
VALUE TO CUSTOMERS
DIFFERENTIATION
FEATURES
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Brand | Honeywell |
Part Number | MIPCG1XX040BSCHX |
Pressure Range | 40 bar |
Shock | 100 G per MIL-STD-202, Method 213, Cond. C at 25deg C |
Current consumption | 6.5 mA +-1 mA |
Accuracy BFSL3 | +-0.25 %FSS |
Typical output resolution | 0.05 % Full Scale Pressure |
Vibration | 20 G sweep, 10 Hz to 2000 Hz at 25deg C |
Electrical connector material | PBT 30 %GF (UL V-0) |
Pressure Port Type | G1/4 A-G3 (ISO 1179-3) |
Over/reverse voltage | +-35 Vdc |
Total Error Band | +-1.0 %FSS (-20deg C to 85deg C) +-2.0 %FSS (-40deg C to 125deg C) |
Supply voltage (Vs) | 8 Vdc to 30 Vdc1 |
Typical response time | 2 ms |
Current | 4 mA to 20 mA |
Startup time | 7 ms |
Ingress protection: Metri-Pack 150 versions | IP65, IP67 |
Wetted materials: port diaphragm external seal for ports | stainless steel 304L stainless steel 316L nitrile -30Deg C to 100deg C |
Cable material (jacket and insulation) | TPE (Thermoplastic Elastomer) flame retardant-type cable is FT1 rated per CSA AWM-I-A/B-II-A/B speci |
Operating temperature range | -40deg C to 125deg C |
Electrical Connector Type | DIN-C, Standard (EN175301-803C) |
Life | >10 million full scale pressure cycles |
Long term stability (1000 hr, 25deg C) | +-0.25 %FSS |
MIPCG1XX010BSCHX Honeywell Pressure Transducers offers a heavy duty and media-isolated pressure transducer in a compact, stainless steel construction for use with a wide range of media including aggressive fluids and water. The Honeywell MIPCG1XX010BSCHX Pressure Transducers provides a cost-competitive solution for wide-ranging potential applications in tough environments.
VALUE TO CUSTOMERS
DIFFERENTIATION
FEATURES
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Accuracy | +-0.25% |
Brand | Honeywell |
Part Number | PX3AN2BF016BSCHL |
Response time | <2 ms |
Dielectric Strength | <1 mA at 1500 Vac |
Product Type | Heavy Duty Pressure Transducer |
Pressure Range | 16 bar |
Electrical Connector Type | Metri-Pack 150, Standard (UL V-0) |
Pressure Reference | Sealed gage |
Housing Body Material | Brass (C36000) |
Operating temperature Range | -40 DegreeC to 125 DegreeC |
Output Transfer Function | Ratiometric: 5.0 V, 10% to 90% Vs |
Output Transfer Function | Current: 4 mA to 20 mA |
Model No. | PX3AN2BF016BSCHL |
Storage temperature range | -40 DegreeC to 125 DegreeC |
Pressure Port Type | 1/8-27 NPT (ANSI/ASME B1.20.1) |
PX3AN2BF016BSCHL Honeywell Pressure Transducer use piezo resistive sensing technology with ASIC(Application Specific Integrated Circuit) signal conditioning in a brass or stainless steel housing and Metri-Pack 150, DIN, or cable harness electrical connections. The Honeywell PX3AG1BS015BSAAX Pressure Transducers, PX3 Series is calibrated and temperature compensated from -40°C to 125°C [-40°Fto 257°F].
POTENTIAL APPLICATIONS
• Industrial: Refrigerant pressure monitoring in HVAC/R systems; dry air system pressure, process controls and automation
• Transportation: Dry air system monitoring; hydraulic, brake, and engine oil fluid pressure monitoring; air brake pressure monitoring
The PX3 Series is not recommended for use with media involving water, saturated air such as steam and vapor, and ammonia.
View Complete details
Product Brochure
Minimum Order Quantity | 1 Piece |
Brand | Honeywell |
Part Number | MIPAG1XX016BSCHX |
Pressure Range | 16 bar |
Pressure Port Type | G1/4 A-G3 (ISO 1179-3) |
Supply voltage (Vs) | 8 Vdc to 30 Vdc1 |
Current consumption | 6.5 mA +-1 mA |
Over/reverse voltage | +-35 Vdc |
Accuracy BFSL3 | +-0.25 %FSS |
Typical output resolution | 0.05 % Full Scale Pressure |
Total Error Band | +-1.0 %FSS (-20deg C to 85deg C) +-2.0 %FSS (-40deg C to 125deg C) |
Operating temperature range | -40 DegreeC to 125 DegreeC |
Life | >10 million full scale pressure cycles |
Electrical Connector Type | Metri-Pack 150, Standard (UL V-0) |
Current | 4 mA to 20 mA |
Long term stability (1000 hr, 25deg C) | +-0.25 %FSS |
Ingress protection: Metri-Pack 150 versions | IP65, IP67 |
Wetted materials: port diaphragm external seal for ports | stainless steel 304L stainless steel 316L nitrile -30deg C to 100deg C |
Typical response time | 2 ms |
Startup time | 7 ms |
Vibration | 20 G sweep, 10 Hz to 2000 Hz at 25deg C |
Electrical connector material | PBT 30 %GF (UL V-0) |
Cable material (jacket and insulation) | TPE (Thermoplastic Elastomer) flame retardant-type cable is FT1 rated per CSA AWM-I-A/B-II-A/B speci |
Shock | 100 G per MIL-STD-202, Method 213, Cond. C at 25deg C |
View Complete details
Product Brochure
Minimum Order Quantity | 1 Piece |
Brand | Honeywell |
Part Number | MIPAG1XX010BSCHX |
Pressure Range | 10 bar |
Supply voltage (Vs) | 8 Vdc to 30 Vdc1 |
Typical response time | 2 ms |
Current | 4 mA to 20 mA |
Electrical Connector Type | Metri-Pack 150, Standard (UL V-0) |
Operating temperature range | -40deg C to 125deg C |
Shock | 100 G per MIL-STD-202, Method 213, Cond. C at 25deg C |
Wetted materials: port diaphragm external seal for ports | stainless steel 304L stainless steel 316L nitrile -30deg C to 100deg C |
Cable material (jacket and insulation) | TPE (Thermoplastic Elastomer) flame retardant-type cable is FT1 rated per CSA AWM-I-A/B-II-A/B speci |
Pressure Port Type | G1/4 A-G3 (ISO 1179-3) |
Ingress protection: Metri-Pack 150 versions | IP65, IP67 |
Over/reverse voltage | +-35 Vdc |
Life | >10 million full scale pressure cycles |
Current consumption | 6.5 mA +-1 mA |
Total Error Band | +-1.0 %FSS (-20deg C to 85deg C) +-2.0 %FSS (-40deg C to 125deg C) |
Typical output resolution | 0.05 % Full Scale Pressure |
Electrical connector material | PBT 30 %GF (UL V-0) |
Accuracy BFSL3 | +-0.25 %FSS |
Long term stability (1000 hr, 25deg C) | +-0.25 %FSS |
Vibration | 20 G sweep, 10 Hz to 2000 Hz at 25deg C |
Startup time | 7 ms |
MIPAG1XX010BSCHX Honeywell Pressure Transducers offers a heavy duty and media-isolated pressure transducer in a compact, stainless steel construction for use with a wide range of media including aggressive fluids and water. The Honeywell MIPAG1XX010BSCHX Pressure Transducers provides a cost-competitive solution for wide-ranging potential applications in tough environments.
VALUE TO CUSTOMERS
DIFFERENTIATION
FEATURES
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Usage/Application | Industry: Refrigerant pressure monitoring in HVAC/R systems, Transportation: Air system monitoring |
Model Name/Number | PX2CG1XX010BSCHX |
Brand | Honeywell |
Voltage | 30V |
Accuracy | +-0.25 %FSS |
Response Time | <2 ms |
Operating Life Cycle | Minimum of 10 million cycles to operating pressure |
Output | 0-5 V |
Operating Temperature | -40 DegreeC to 125 DegreeC |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Usage/Application | Industry: Refrigerant pressure monitoring in HVAC/R systems, Transportation: Air system monitoring |
Model Name/Number | PX2CG1XX070BSCHX |
Brand | Honeywell |
Voltage | 30V |
Accuracy | +-0.25 %FSS |
Operating Range | 1-24 bar |
Response Time | <2 ms |
Life Cycle | Minimum of 10 million cycles to operating pressure |
Output | 0-5 V |
operating Temperature | -40 DegreeC to 125 DegreeC |
Pressure reference | Absolute, sealed gage or vented gage |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Usage/Application | Industry: Refrigerant pressure monitoring in HVAC/R systems, Transportation: Air system monitoring |
Model Name/Number | PX2CG1XX010BACHX |
Brand | Honeywell |
Voltage | 30V |
Accuracy | +-0.25 %FSS |
Operating Range | -40 DegreeC to 125 DegreeC |
Response Time | <2 ms |
Pressure reference | Absolute, sealed gage or vented gage |
Life cycle | Minimum of 10 million cycles to operating pressure |
output | 0-5 V |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Usage/Application | Industry: Refrigerant pressure monitoring in HVAC/R systems, Transportation: Air system monitoring |
Model Name/Number | PX2CG1XX025BSCHX |
Brand | Honeywell |
Voltage | 30V |
Accuracy | +-0.25 %FSS |
Operating Range | 1-24 bar |
Response Time | <2 ms |
Pressure reference | Absolute, sealed gage or vented gage |
operating Temperature | -40 DegreeC to 125 DegreeC |
Output | 0-5 V |
Life Cycle | Minimum of 10 million cycles to operating pressure |
View Complete details
Minimum Order Quantity: 01 Piece
Product Brochure
Brand | Honeywell |
Voltage | 9.5 to 30.0 V |
Accuracy | 0.25 % |
Model Number/Name | PX3AG1BS015BSAAX |
Output Signal (mA) | 4-20 |
Sensor Material | Brass |
Condition | New |
Pressure Range | 0 to 15 bar |
Working Temperature | -40 to 125 Celsius (oC) |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Usage/Application | Industrial: Refrigerant pressure monitoring in HVAC/R systems; dry air system pressure |
Model Name/Number | PX3CG1SS001BACHX |
Brand | Honeywell |
Voltage | 30V |
Accuracy | +-0.25 %FSS |
Operating Range | -1 to 0 bar |
Response Time | <2 ms |
Operating Temperature | -40 DegreeC to 125 DegreeC |
Ambient Humidity | 0 %RH to 95 %RH, Non-condensing |
Compliance | RoHS, REACH, and CE |
Life Cycle | >10 Million full scale pressure cycles over the Calibrated pressure range |
Output | 4-20 mA , 0-5 V |
Current consumption | 3.5 mA max |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Usage/Application | Industrial: Refrigerant pressure monitoring in HVAC/R systems; dry air system pressure |
Model Name/Number | PX3CG1SS002BACHX |
Brand | Honeywell |
Voltage | 30V |
Accuracy | +-0.25 %FSS |
Operating Range | -1 to 1bar |
Response Time | <2 ms |
Life Cycle | >10 million full scale pressure cycles over the calibrated pressure range |
Operating Temperature | -40 DegreeC to 125 DegreeC |
Output | 4-20 mA , 0-5 V |
Current Consumption | 3.5 mA max |
Ambient Humidity | 0 %RH to 95 %RH, non-condensing |
Compliance | RoHS, REACH, and CE |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Usage/Application | Industrial: Refrigerant pressure monitoring in HVAC/R systems; dry air system pressure |
Model Name/Number | PX3CG1SS004BACHX |
Brand | Honeywell |
Voltage | 30V |
Accuracy | +-0.25 %FSS |
Operating Range | -1 to 3 bar |
Response Time | <2 ms |
Ambient Humidity | 0 %RH to 95 %RH, non-condensing |
Life cycle | >10 million full scale pressure cycles over the calibrated pressure range |
Output | 4-20 mA , 0-5 V |
Current Consumption | 3.5 mA max |
Pressure Range | -1 to 9 |
Operating Temperature | -40 DegreeC to 125 DegreeC |
Compliance | RoHS, REACH, and CE |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Usage/Application | Industrial: Refrigerant pressure monitoring in HVAC/R systems; dry air system pressure |
Model Name/Number | PX3CG1SS006BACHX |
Brand | Honeywell |
Voltage | 30V |
Accuracy | +-0.25 %FSS |
Operating Range | -1 to 5 bar |
Response Time | <2 ms |
Operating Temperature | -40 DegreeC to 125 DegreeC |
Current Consumption | 3.5 mA max |
Compliance | RoHS, REACH, and CE |
Life cycle | >10 Million full scale pressure cycles over the calibrated pressure range |
Ambient Humidity | 0 %RH to 95 %RH, Non-condensing |
Output | 4-20 mA , 0-5 V |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Usage/Application | Industrial: Refrigerant pressure monitoring in HVAC/R systems; dry air system pressure |
Model Name/Number | PX3CG1SS010BACHX |
Brand | Honeywell |
Voltage | 30V |
Accuracy | +-0.25 %FSS |
Operating Range | -1 to 9 bar |
Response Time | <2 ms |
Life Cycle | >10 million full scale pressure cycles over the calibrated pressure range |
Output | 4-20 mA , 0-5 V |
Current Consumption | 3.5 mA max |
Compliance | RoHS, REACH, and CE |
Operating Temperature | -40 DegreeC to 125 DegreeC |
Ambient Humidity | 0 %RH to 95 %RH, non-condensing |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Usage/Application | Industrial: Refrigerant pressure monitoring in HVAC/R systems; dry air system pressure |
Model Name/Number | PX3CG1SS010BSCHX |
Brand | Honeywell |
Voltage | 30V |
Accuracy | +-0.25 %FSS |
Operating Range | 0 to 10 bar |
Response Time | <2 ms |
Operating Temperature | -40 DegreeC to 125 DegreeC |
Life Cycle | >10 Million full scale pressure cycles over the Calibrated pressure range |
Output | 4-20 mA , 0-5 V |
Current Consumption | 3.5 mA max |
Ambient Humidity | 0 %RH to 95 %RH, Non-condensing |
Compliance | RoHS, REACH, and CE |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Usage/Application | Industrial: Refrigerant pressure monitoring in HVAC/R systems; dry air system pressure |
Model Name/Number | PX3CG1SS025BSCHX |
Brand | Honeywell |
Voltage | 30V |
Accuracy | +-0.25 %FSS |
Operating Range | 0 to 25 bar |
Response Time | <2 ms |
Current Consumption | 3.5 mA max |
Compliance | RoHS, REACH, and CE |
Operating Temperature | -40 DegreeC to 125 DegreeC |
Life Cycle | >10 Million full scale pressure cycles over the Calibrated pressure range |
Ambient Humidity | 0 %RH to 95 %RH, non-condensing |
Output | 4-20 mA , 0-5 V |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Usage/Application | Industrial: Refrigerant pressure monitoring in HVAC/R systems; dry air system pressure |
Model Name/Number | PX3CG1SS016BSCHX |
Brand | Honeywell |
Voltage | 30V |
Accuracy | +-0.25 %FSS |
Operating Range | 0- 16 bar |
Response Time | <2 ms |
Compliance | RoHS, REACH, and CE |
Life Cycle | >10 Million full scale pressure cycles over the Calibrated pressure range |
Ambient Humidity | 0 %RH to 95 %RH, Non-condensing |
Operating Temperature | -40 DegreeC to 125 DegreeC |
Output | 4-20 mA , 0-5 V |
Current Consumption | 3.5 mA max |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Usage/Application | Industrial: Refrigerant pressure monitoring in HVAC/R systems; dry air system pressure |
Model Name/Number | PX3CG1SS040BSCHX |
Brand | Honeywell |
Voltage | 30V |
Accuracy | +-0.25 %FSS |
Operating Range | 0 to 40 bar |
Response Time | <2 ms |
Life Cycle | >10 Million full scale pressure cycles over the Calibrated pressure range |
Current Consumption | 3.5 mA max |
Compliance | RoHS, REACH, and CE |
Operating temperature | -40 DegreeC to 125 DegreeC |
Output | 4-20 mA , 0-5 V |
Ambient Humidity | 0 %RH to 95 %RH, non-condensing |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Work Pressure | 0-250 bar |
IP Rating | IP65 |
Pressure Type | Sealed Guage Pressure |
Output Type | Analog |
Output Voltage | 0-10 V |
Series | GPT |
View Complete details
Minimum Order Quantity: 01 Piece
Product Brochure
Usage/Application | Industrial |
Model Name/Number | PX2CG1XX004BACHX |
Brand | Honeywell |
Voltage | 24V |
Accuracy | 2% |
Part Type | PX2 |
Additional Information:
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Usage/Application | Industrial: Refrigerant pressure monitoring in HVAC/R systems. air compressor system pressure |
Model Name/Number | PX2CG1XX001BACHX |
Brand | Honeywell |
Voltage | 30V |
Accuracy | +-0.25 %FSS |
Operating Range | : 1 bar to 70 bar | 100 kPa to 7 MPa | 15 psi to 1000 psi |
Response Time | <2 ms |
Electrical connector types | Metri-Pack 150 (UL 94 HB or V-0 options), Micro M12, DIN, Deutsch, or |
Operating Temperature | -40 DegreeC to 125 DegreeC |
Output | 0-5 V |
Pressure reference | Absolute, sealed gage or vented gage |
Life Cycle | Minimum of 10 million cycles to operating pressure |
View Complete details